This website uses cookies

We use cookies to show you the right content for your language and devices (Necessary), to present content selected for you (Preferences), to analyse traffic to our website (Statistics) and to offer you our best special offers on other websites (Marketing).

By clicking on "ACCEPT", you consent to the use of cookies. You can change or revoke your cookie settings at any time in the footer under "Cookie settings". You can find detailed information in our privacy policy.

  • Diese Cookies sind für die Funktionalität unserer Website erforderlich und können nicht deaktiviert werden (z.B. SessionCookies).

  • Diese Cookies ermöglichen es unter anderem, Ihnen Ihre zuvor angesehenen Artikel anzuzeigen und ähnliche Artikel zu empfehlen. Weitere Informationen erhalten Sie in unserer Datenschutzerklärung und der des jeweiligen Anbieters.

  • Diese Cookies helfen uns zu verstehen, wie Besucher mit unserer Webseite interagieren. Die Informationen werden anonym gesammelt und analysiert. Je nach Tool werden ein oder mehrere Cookies des gleichen Anbieters gesetzt. Weitere Informationen erhalten Sie in unserer Datenschutzerklärung und der des jeweiligen Anbieters.

  • Diese Cookies benötigen wir, um Ihnen z. B. auf anderen Websites unsere Werbung anzuzeigen. Deaktivieren Sie sie, wird Ihnen stattdessen andere Werbung angezeigt. Weitere Informationen erhalten Sie in unserer Datenschutzerklärung und der des jeweiligen Anbieters.

In order to design our website optimally for you and to be able to improve it continuously, we use cookies. By continuing to use the website, you agree to the use of cookies. For more information on cookies, please see our privacy policy.

Zum Inhalt springen

Never plug in several extension leads one after the other

Is it allowed to connect several extension leads in series?

One television, two computers and numerous household and kitchen appliances– but there is no power socket close at hand. In this case, many people resort to using an extension lead.

An extension lead has many advantages; on the one hand, it offers many connection options for your devices, whether with two, six or even ten sockets. On the other hand, it serves as a kind of extension cable and can therefore be used in a flexible form.

So far so good – but what do you do if the cable is too short? Or if a socket strip still has too few sockets? Connecting a second strip would be a great idea, wouldn’t it? This way, you could add additional sockets or an extension cable and the problem would be solved.

However, before you think about simply adding a second socket strip, you should know that you should generally not connect socket strips one after another. This must (according to VDE 0620) even be noted on the socket strip by means of the “do not connect one after another” warning.

Check the maximum power of your extension lead

The strip’s power capacity is usually indicated on every socket strip; it is usually about 3,500 Watt. This power must never be exceeded in the home power grid.

Calculate how many devices you can connect

On your devices, you will also find the relevant power on the so-called “type plate”. For example, you use the following devices at the same time by means of a socket strip:

  • Kettle  approx. 2.000 Watt
  • Coffee machine approx. 900 Watt
  • Microwave approx. 1.000 Watt

The total of all power values is 3,900 Watt. However, as the maximum power that can be supplied by the socket strip is approx. 3,500 Watt, it will be overloaded with 3,900 Watt.

If a second socket strip is connected, the power consumption will not be distributed between the two socket strips but only accumulates at one socket strip. Thus, the load will quickly add up to a high total and the strip will be overloaded.

Why is an overload so dangerous?

Many people think that the fuse will blow in case of an overload. This is correct, however only in case the specified current flow is considerably exceeded. This means that the fuse may only be blown after the socket strip has already been overloaded for a longer period.
In case a socket strip is overloaded, it may already heat up to up to 200 degrees after few minutes, which could cause a so-called “smouldering fire”. A smouldering fire differs from a normal fire in that there are no visible flames. A fire of this kind is so dangerous as it cannot easily be identified. Dust or other easily flammable materials may then start a flaming fire and – in the worst case – may lead to the further spreading of this fire and the complete surrounding catching fire.